<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-13T17:12:38Z</responseDate>
  <request identifier="oai:hirokoku-u.repo.nii.ac.jp:00000347" verb="GetRecord" metadataPrefix="jpcoar_1.0">https://hirokoku-u.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:hirokoku-u.repo.nii.ac.jp:00000347</identifier>
        <datestamp>2024-07-22T07:29:29Z</datestamp>
        <setSpec>16:66:77</setSpec>
      </header>
      <metadata>
        <jpcoar:jpcoar xmlns:datacite="https://schema.datacite.org/meta/kernel-4/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcndl="http://ndl.go.jp/dcndl/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:jpcoar="https://github.com/JPCOAR/schema/blob/master/1.0/" xmlns:oaire="http://namespace.openaire.eu/schema/oaire/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:rioxxterms="http://www.rioxx.net/schema/v2.0/rioxxterms/" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns="https://github.com/JPCOAR/schema/blob/master/1.0/" xsi:schemaLocation="https://github.com/JPCOAR/schema/blob/master/1.0/jpcoar_scm.xsd">
          <dc:title xml:lang="ja">定位放射線治療における品質管理サポートシステムの構築</dc:title>
          <dc:title xml:lang="en">Development of quality control support system for stereotactic radiation therapy</dc:title>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">田邉, 悦章</jpcoar:creatorName>
            <jpcoar:creatorName xml:lang="ja-Kana">タナベ, ヨシノリ</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">大倉, 保彦</jpcoar:creatorName>
            <jpcoar:creatorName xml:lang="ja-Kana">オオクラ, ヤスヒコ</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName xml:lang="ja">石田, 隆行</jpcoar:creatorName>
            <jpcoar:creatorName xml:lang="ja-Kana">イシダ, タカユキ</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:subject subjectScheme="Other">定位放射線治療</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">画像処理</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">品質保証</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">品質管理</jpcoar:subject>
          <datacite:description xml:lang="en" descriptionType="Abstract">Stereotactic radio therapy (SRT) using a linear Accelerator (Linac) requires high precision in the table position and the center of irradiation. QC procedure is necessary To guarantee high precision of each SRT. As the QC procedure, we use the film shot method, in which the table correction width is derived from target images taken at various gantry angles and table angles. However, QC procedure is so complex that long time is wasted for this procedure. In addition, the degree of precision of QC procedure depends on each technologist. We developed a QC program support system to support QC procedure. This system processes images taken by the film shot method, and outputs the table correction width to adjust target position. For evaluation of our developed system, we compared correction width of obtained from our system with that from, conventional manual operation. Results showed that high degree of precision was achieved by employing our system. By using our system, one double check scheme, QC procedure by using both manual operation and our system, will be realized without any additional time for the procedure.</datacite:description>
          <dc:publisher>広島国際大学大学院総合人間科学研究科医療工学専攻</dc:publisher>
          <datacite:date dateType="Issued">2007-03-15</datacite:date>
          <dc:language>jpn</dc:language>
          <dc:type rdf:resource="http://purl.org/coar/resource_type/c_6501">departmental bulletin paper</dc:type>
          <oaire:version rdf:resource="http://purl.org/coar/version/c_970fb48d4fbd8a85">VoR</oaire:version>
          <jpcoar:identifier identifierType="DOI">https://doi.org/10.60172/00000341</jpcoar:identifier>
          <jpcoar:identifier identifierType="URI">https://hirokoku-u.repo.nii.ac.jp/records/347</jpcoar:identifier>
          <jpcoar:identifierRegistration identifierType="JaLC">10.60172/00000341</jpcoar:identifierRegistration>
          <jpcoar:sourceIdentifier identifierType="NCID">AA12217173</jpcoar:sourceIdentifier>
          <jpcoar:sourceIdentifier identifierType="PISSN">1881-9265</jpcoar:sourceIdentifier>
          <jpcoar:sourceTitle>医療工学雑誌</jpcoar:sourceTitle>
          <jpcoar:sourceTitle xml:lang="en">Journal of Medical Engineering</jpcoar:sourceTitle>
          <jpcoar:issue>1</jpcoar:issue>
          <jpcoar:pageStart>45</jpcoar:pageStart>
          <jpcoar:pageEnd>49</jpcoar:pageEnd>
          <jpcoar:file>
            <jpcoar:URI label="jme01_045.pdf">https://hirokoku-u.repo.nii.ac.jp/record/347/files/jme01_045.pdf</jpcoar:URI>
            <jpcoar:mimeType>application/pdf</jpcoar:mimeType>
            <jpcoar:extent>524.8 kB</jpcoar:extent>
            <datacite:date dateType="Available">2023-03-11</datacite:date>
          </jpcoar:file>
        </jpcoar:jpcoar>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>